SJI & SDI CERTIFIED — BUILT FOR PERFORMANCE. VIEW CERTIFICATIONS ↗
Altra Steel / Structural Systems

LH-Series
Bar Joists

Open-web steel joists designed for long-span conditions and heavier loads where project-specific structural requirements call for added reach and support.

Overview

Long-span Support for Heavier Loads

LH-Series bar joists are designed for longer spans and framing conditions that require support for heavier loads. Their open-web configuration can accommodate applications where other joist systems may not meet the project requirements.

The supplied LH-Series reference describes nominal joist depths from 18 to 48 inches and spans up to 96 feet. Final dimensions, member selection, connections and required bridging are determined by project-specific engineering.

Nominal depth range

18–48 in.

Span capability

Up to 96 ft.

System

Open-web steel joists

Primary application

Long spans & heavier loads

Quality & Standards

We Carry SJI-Certified Joists

Every open-web steel joist we supply is fabricated to meet specifications by Steel Joist Institute (SJI) members—providing confidence in consistent quality and recognized industry requirements.

Construction Reference

Connection & Bridging Details

The six typical references below show LH joist bracing, bridging and bearing connections. Each diagram illustrates a different coordination point to review with the approved engineering and shop drawings.

DETAIL 01

X-Brace Connection

SCALE: N/S

Illustrates a typical X-brace arrangement where diagonal members connect at the joist framing. Use this reference to locate brace connections and fastening points.

Expand ↗
DETAIL 02

X BRACE BRIDGING

SCALE: N/S

Shows diagonal crossing bridging between adjacent joists. This reference identifies how the bridging members are attached and coordinated.

Expand ↗
DETAIL 03

BOTTOM CHORD HORIZONTAL BRIDGING

SCALE: N/S

Depicts a typical bottom-chord horizontal bridging member and the end condition used to connect adjacent joists.

Expand ↗
DETAIL 04

HORIZONTAL BRIDGING

SCALE: N/S

Shows the horizontal bridging layout between joists, clarifying the direction and relationship of the bridging members.

Expand ↗
DETAIL 05

JOIST TO STEEL BEAM CONNECTION

SCALE: N/S

Illustrates a typical bearing and fastening arrangement where an LH joist meets a steel beam. Final connection requirements follow approved documents.

Expand ↗
DETAIL 06

JOIST TO COLUMN CONNECTION

SCALE: N/S

Shows the relationship between the joist support and a structural column, including typical bearing and fastening locations.

Engineering note: Details are typical references, not project-specific instructions. Connections, bracing and bridging must follow the approved structural and erection drawings.

Start Your Project

Need LH-Series Bar Joists?

Send your structural drawings or project requirements to our estimating team for a project-specific quotation.

LH-Series Technical Data

Joist Designations & Approximate Weights

Review LH-Series designations by nominal depth and the approximate weights shown in the supplied reference chart.

How to read the table: 18LH02 identifies an LH-Series joist with a nominal 18-inch depth. The corresponding weight is shown in pounds per linear foot (lb/ft). Final selection depends on structural loads, long-span requirements and project specifications.

Nominal Depth

Joist Designation / Approximate Weight

18 in.

18LH02
10 lb/ft

18LH03
11 lb/ft

18LH04
12 lb/ft

18LH05
15 lb/ft

18LH06
15 lb/ft

18LH07
17 lb/ft

18LH08
19 lb/ft

18LH09
21 lb/ft

20 in.

20LH02
10 lb/ft

20LH03
11 lb/ft

20LH04
12 lb/ft

20LH05
15 lb/ft

20LH06
15 lb/ft

20LH07
17 lb/ft

20LH08
19 lb/ft

20LH09
21 lb/ft

20LH10
23 lb/ft

24 in.

24LH03
11 lb/ft

24LH04
12 lb/ft

24LH05
13 lb/ft

24LH06
16 lb/ft

24LH07
17 lb/ft

24LH08
18 lb/ft

24LH09
21 lb/ft

24LH10
23 lb/ft

24LH11
25 lb/ft

28 in.

28LH05
13 lb/ft

28LH06
16 lb/ft

28LH07
17 lb/ft

28LH08
18 lb/ft

28LH09
21 lb/ft

28LH10
23 lb/ft

28LH11
25 lb/ft

28LH12
27 lb/ft

28LH13
30 lb/ft

32 in.

32LH06
14 lb/ft

32LH07
16 lb/ft

32LH08
17 lb/ft

32LH09
21 lb/ft

32LH10
21 lb/ft

32LH11
24 lb/ft

32LH12
27 lb/ft

32LH13
30 lb/ft

32LH14
33 lb/ft

32LH15
35 lb/ft

36 in.

36LH07
16 lb/ft

36LH08
18 lb/ft

36LH09
21 lb/ft

36LH10
21 lb/ft

36LH11
23 lb/ft

36LH12
25 lb/ft

36LH13
30 lb/ft

36LH14
36 lb/ft

36LH15
36 lb/ft

40 in.

40LH08
16 lb/ft

40LH09
21 lb/ft

40LH10
21 lb/ft

40LH11
22 lb/ft

40LH12
25 lb/ft

40LH13
30 lb/ft

40LH14
35 lb/ft

40LH15
36 lb/ft

40LH16
42 lb/ft

44 in.

44LH09
19 lb/ft

44LH10
21 lb/ft

44LH11
22 lb/ft

44LH12
25 lb/ft

44LH13
30 lb/ft

44LH14
31 lb/ft

44LH15
36 lb/ft

44LH16
42 lb/ft

44LH17
47 lb/ft

48 in.

48LH10
21 lb/ft

48LH11
22 lb/ft

48LH12
25 lb/ft

48LH13
29 lb/ft

48LH14
32 lb/ft

48LH15
36 lb/ft

48LH16
42 lb/ft

48LH17
47 lb/ft

Dimensions, weights and design requirements should be verified against current SJI specifications and final engineering and fabrication documents before ordering.

Project Coordination

From Drawings to Fabrication

01 / Approval Drawings

Document Review

We review contract documents and prepare joist drawings for coordination.

02 / Review

Design-Team Review

Shop drawings are submitted to resolve missing information and discrepancies.

03 / BOM Fabrication

Fabrication Details

Following approval, detailed material information is prepared for fabrication.

04 / Field Use Plans

Installation Support

Field-use documentation supports erection planning and coordination.

TECHNICAL LIBRARY

Resources for better project decisions.

Access product documentation and technical information to support your design, specification and purchasing process.

Have structural plans? Let’s talk steel.

Send your requirements to our estimating team for a project-based quote.